Epoxy resin for use as a primer or construction resin. A solvent-free product for priming walls and floors and creating the so-called epoxy screeds.
Order in bulk with free advice
Get a discount for your company by talking to an advisor.
Two-component waterproofing membrane for application to smooth substrates. Rain-resistant just 2 hours after application . Creates a coating resistant to moisture and mechanical damage. Perfect for roofs, balconies and terraces.
Do you have any questions? Call:
+48 717 026 346
Neoproof Polyurea C1 is a two-component, extremely durable polyurea waterproofing membrane for cold application with a brush, roller, or airless spray. Thanks to its special formula, it can be applied in a single layer (on smooth substrates such as concrete or steel). Suitable for use as waterproofing on roofs, balconies, and terraces where mechanical resistance and excellent waterproofing properties are required. It creates a smooth (bubble-free), moisture-impermeable polyurea insulation, exhibiting zero water absorption and resistance to mechanical damage. This liquid waterproofing coating, based on aliphatic resins, is fully UV-resistant and requires no additional topcoats. Rain can fall on the coating within two hours of application, making the product suitable for use in unpredictable weather conditions.
The product can be applied to a variety of substrates using the appropriate primer
Primers should be used in accordance with their technical data sheets.
Roofing felt – not recommended for use on roofing felt (requires application of 1.5 kg/m² of product in two layers). Ideal for application on surfaces with an even/uniform structure.
Concrete/cementitious substrates: Acqua Primer NP - base primer, however, due to its water-soluble nature, it requires favorable weather conditions. Max. permissible substrate moisture content: 8%. Recoating time: 24 hours. Epoxol Primer – in unfavorable weather conditions (high humidity, low temperature), we recommend using a solvent-based epoxy primer. Max. permissible substrate moisture content: 4%. Recoating time: 24 hours. Neodur Fast Track PR - for projects where time is of the essence and must be completed quickly. Max. permissible substrate moisture content: 4%. Recoating time: 2 hours. Neopox Primer WS - fresh concrete (minimum 2 weeks) or damp from rainfall, washing, etc. (moisture comes from the outside, not the ground), there is no time for the substrate to dry. Max. permissible substrate moisture content: <100%. Time to repaint: 24 hours Neopox Primer AY - if there is a problem with capillary moisture rising from the ground (e.g. terrace on ground with poorly executed or no insulation). Maximum permissible substrate moisture: 10-12%. Time to repaint: 24 hours
Black steel - Neopox Primer 815. Neodur Metalforce rust remover 24 hours before priming .
Steel or other metal already painted, for example with polyurethane or polyvinyl paint Neodur Metalforce rust remover 24 hours before priming .
Steel factory-coated with a polyester coating – the surface should be roughened and washed with high-pressure water. After drying, prime with Neopox Primer 815. Neodur Metalforce rust remover for 24 hours before priming .
Galvanized steel, aluminum - Neotex Inox Primer Neodur Metalforce rust remover 24 hours before priming .
New, closed-cell PUR foam in good condition should be applied directly, without primer, in one thick layer. The foam should have a relatively even surface to prevent the Neoproof Polyurea from flowing into the grooves, as this will cause localized bubbles (the solvent will try to escape). If there are shiny areas on the foam, they should be matted and treated with Acqua Primer NP , as well as any areas with open pores.
PUR foam, old in poor condition, open cells - Acqua Primer NP .
Old elastomeric coatings/membranes, such as Neoroof and Neoproof PU W-40 - thoroughly wash with water under pressure, dry and apply Neoproof Polyurea directly.
Wood – the wooden structure must be rigid and not bend excessively. Use Epoxol Primer . If the wood is highly absorbent, additional priming may be necessary (after the first priming, the wood will absorb everything and will remain dull or unevenly glossy).
PVC membranes - wash the substrate with THF, MEK, or Neotex 1021 (in this order, from most effective to slowest). After slightly dissolving the membrane, apply Neoproof Polyurea directly to the slightly sticky PVC membrane.
Hot-applied aromatic polyurea - Relatively new, in good condition - buff to remove shine, remove dust after buffing, and apply directly. Older, chalky surfaces - pressure-wash to remove chalking residue, then apply directly. Coated with a polyurethane membrane for UV protection - pressure-wash and apply directly.
Waterproofing a flat roof insulated with PUR foam:
| Product | NEOPROOF POLYUREA R | NEOPROOF POLYUREA C1 | NEOPROOF PU W-40 | NEOPROOF PU FAST -30 | NEOROOF | |
| Resistance to early rain | After 1 hour | After 2 hours | Lack | After 1 hour | Lack | |
| Temperature range during application | +5°C to +35°C | +5°C to +35°C | +5°C to +40°C | +5°C to +40°C | +12°C to +40°C | |
| Wear | Bye Bye | 1.5-1.6 kg/m2 for two layers (without reinforcing non-woven fabric) 2.5-3 kg/m2 for three layers (with reinforcing non-woven fabric) |
1.5 kg/m2 in two layers | 1.5-1.6 kg/m2 bituminous substrates, without reinforcing non-woven fabric 2.5-3 kg/m2 degraded bituminous substrates, with reinforcing non-woven fabric |
1.5-1.6 kg/m2 bituminous substrates, without reinforcing non-woven fabric 2.5-3 kg/m2 degraded bituminous substrates, with reinforcing non-woven fabric |
1.5-1.6 kg/m2 for two layers 2.5 kg/m2 degraded substrates, application with reinforcing non-woven fabric |
| Concrete | 1.2 kg/m2 for two layers (flat surface) | 0.75 kg/m2 in one layer | 1.2-1.3 kg/m2 | 1.2-1.3 kg/m2 | 0.7 kg/m2 for two layers (also cement surface) | |
| Metal | 1.2 kg/m2 for two layers (flat surface) | 0.75 kg/m2 in one layer | 1.2-1.3 kg/m2 (also PUR foam, polystyrene) | 1.2-1.3 kg/m2 (also PUR foam, polystyrene) | 0.5-0.7 kg/m2 (also PUR foam, Styrofoam, without mesh) | |
| Estimated durability of the coating | 2 layers >20 years 2 layers with Neotextile mesh >25 years |
1 layer >20 years | 2 layers >11 years 3 layers >12 years 3 layers with Neotextile >20 years |
2 layers >11 years 3 layers >12 years 3 layers with Neotextile >20 years |
2 layers >10 years 3 layers >12 years 3 layers with Neotextile mesh >15 years |
|
| Time to apply the next layer | +5°C - 24 h +23°C - 18 h +35°C - 10 h |
+5°C - 24 h +23°C - 18 h |
24 hours | +10°C - 5 h +23°C - 3 h +35°C - 2 h |
24 hours | |
| Type of membrane | Poliurecznikowa 2K | Poliurecznikowa 2K | Polyurethane 1K | Polyurethane 1K | Hybrid 1K | |
| Dispersion | Solvent-based | Solvent-based | Aqueous | Aqueous | Aqueous | |
| Temperature range in which the coating retains its properties | -35°C to +80°C | -35°C to +80°C | -40°C to +80°C | -30°C to +80°C | -35°C to +80°C | |
| Cool Material Certificate | YES | Lack | YES | YES | YES | |
| Broof classification (t1) | YES | Lack | YES | Lack | YES | |
| European Technical Assessment (ETA 24/1246) | YES - the highest durability class W3 (service life up to 25 years for a non-reinforced system with a thickness of 1 mm and a reinforced system with a thickness of 1.2 mm) | Lack | Lack | Lack | YES - the highest durability class W3 (service life up to 25 years for a 1.2 mm thick reinforced system) | |
Do you have any questions? We will help you choose the perfect product to use.
Call:
+48 717 026 346
0.75 kg/m2
20 kg
Solvent-based
4 h (23 o C)
Get a discount for your company by talking to an advisor.
Proven products
Here you will find products with high strength and technical parameters. Thanks to this, you can enjoy long-lasting effects.
Help in choosing
Are you wondering which products will be best for your needs? Call us - we will advise you and choose the right solution.
Contractor support
Do you need help with construction work? Let us know and we will recommend proven contractors.
Stationary points